The Chromatography facility was created in 1988 in order to fulfill the needs of CIB and external users. The current Chromatography and Mass Spectrometry Service of the CIB-Margarita Salas (CEM-CIB) emerged in 2023 as an expansion of the previous Gas Chromatography Facility with incorporation of new equipments of gas and liquid chromatograhs. Chromatography is indicated for the separation, identification and quantification of substances present in complex samples; Mass Spectrometry also allows obtaining information about the mass and structure of the analyzed compounds. So this technique coupled with Chromatography increases analytical possibilities.

Some routine analyses performed at the CEM-CIB facility are:

Gas Chromatography

     Separation and characterization of:

  • TMS derivatives/oximes of carbohydrates

  • Alditol acetates

  • Trimethylsilyl derivatives of several compounds

  • Volatile fatty acids

  • Essential oils

  • Steroids

  • Polihydroxialcanoates

 

 

        Liquid Chromatography: 

                - Proteins purification.

    - Organic Compounds purification.

    - Metabolomic.

    - Measurement of molecular weight, size and structure of polymers (GPC)

Other protocols can be set up on users demand. 

 

Instruments

  • Gas chromatograph 7890A (Agilent) equipped with a Flame Ionization Detector, Thermal Conductivity Detector, autosampler (150 vials) and Headspace Sampler 7697A (Agilent).

  • Gas chromatography-mass spectrometry system (GC-MS) 7980A-5975C from Agilent for analysis of volatile samples of low molecular weight and autosampler (150 vials).

  • GC INTUVO 9000 con FID.

  • INTUVO-MS5977B Inert Plus MSD Turbo.

  • 1260 GPC/SEC MDS-Chloroform (Agilent).

  • LC/MS Single Quadrupole 1260 INFINITY II-MSD XT (Agilent)

  • Preparative LC Systems Agilent 1260 INFINITY II and ÄKTA pure 150M (Cytiva).

  • 2D-LC/Q-TOF Agilent 1260 INFINTY II-6546 LC/Q-TOF.

  • Sample Prep WorkBench 7696A (Agilent).

 

Instructions

Internal Users

For Liquid Chromatography services, as well as for the use of GC-FID-HS equipment, users must first contact the Service staff via email (cromatografia@cib.csic.es) or phone (Ext 442696).

For GC-MS equipment, users must make a reservation through the corresponding calendar on the CIB Reservation Server following the following RULES.

External Users

For the use of the Service, users external to CIB-Margarita Salas must first contact the staff via email (cromatografia@cib.csic.es) or phone (911 09 80 96).

In all cases, samples must be accompanied by the filled and signed corresponding Request Form:

REQUEST FORM GC ANALYSIS

REQUEST FORM GPC ANALYSIS

REQUEST FORM LC ANALYSIS

 

The Service fees can be consulted below:

CIB FEES

EXTERNAL FEES

 

 

 

Members

Technical Staff
Leonor Rodríguez Sánchez